Product picturePart #Description
150963TELSEC MINI - An Ethernet 10 Base-T RJ45 connector enabled monitoring system that supports 6 universal inputs and 2 digital outputs. The unit supports both wall or rack mounting and supports 24 or 48 VDC. For rack mounting, order pn#150990 bracket kit.
150998-8TELSEC MINI Pro-8 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 8 universal inputs and 4 digital outputs. The system has an RS485 serial port included to monitor Modbus RTU devices. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-16TELSEC MINI Pro-16 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 16 universal inputs and 4 digital outputs. The system has an RS485 serial port included to monitor Modbus RTU devices. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-24TELSEC MINI Pro-24 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 24 universal inputs and 4 digital outputs. The system has an RS485 serial port included to monitor Modbus RTU devices. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-32TELSEC MINI Pro-32 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 32 universal inputs and 4 digital outputs. The system has an RS485 serial port included to monitor Modbus RTU devices. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-8-1TELSEC MINI Pro-8 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 8 universal inputs and 4 digital outputs. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-16-1TELSEC MINI Pro-16 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 16 universal inputs and 4 digital outputs. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-24-1TELSEC MINI Pro-24 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 24 universal inputs and 4 digital outputs. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150998-32-1TELSEC MINI Pro-32 - An Ethernet 10/100 Base-T RJ45 connector enabled monitoring system that supports 32 universal inputs and 4 digital outputs. The unit supports both wall or rack mounting and has dual feed power at 24 or 48 VDC. For rack mounting, order pn#150989 bracket kit.
150612TELSEC® 2000 WM - A wall mountable monitoring and control system with 32 universal inputs, 16 digital outputs, RS232 port, card access reader port and bus port to network to an expansion module (WME). Includes Temperature & Humidity Sensor.
150617TELSEC® 1500 WM - A wall mountable monitoring and control system with 16 universal inputs, 8 digital outputs, RS232 port, card access reader port and bus port to network to an expansion module (WME). Includes Temperature & Humidity Sensor.
150618TELSEC® 2000 RM - A rack mountable monitoring and control system with 32 universal inputs, 16 digital outputs, RS232 port, card access reader port and bus port to network to an expansion module (RME). Includes Temperature & Humidity Sensor.
150619TELSEC® 1500 RM - A rack mountable monitoring and control system with 16 universal inputs, 8 digital outputs, RS232 port, card access reader port and bus port to network to an expansion module (RME). Includes Temperature & Humidity Sensor.
150640TELSEC® RME - A rack mountable expansion module which can be networked via the expansion port on a TELSEC® 1500RM or TELSEC® 2000RM to provide an additional 32 universal inputs and 16 digital outputs.
150724TELSEC® WME - A wall mountable expansion module which can be networked via the expansion port on a TELSEC® 1500WM or TELSEC® 2000WM to provide an additional 32 universal inputs and 16 digital outputs.
150794-100TELSEC® Digital Input Expansion Module (DIEM-100) - A rack mountable expansion module which can be networked via the expansion port on a TELSEC® 2000RM/WM to provide an additional one hundred (100) discrete inputs for monitoring of environmental and critical equipment alarms. This module requires four (4) Interconnect Cables (pn# 300815 series cables) and either one (1) HD Wiring Block (pn# 300723) or one (1) Wiring Block (pn# 300718). (all sold separately)
no picture150794-150TELSEC® Digital Input Expansion Module (DIEM-150) - A rack mountable expansion module which can be networked via the expansion port on a TELSEC® 2000RM/WM to provide an additional one hundred-fifty (150) discrete inputs for monitoring of environmental and critical equipment alarms. This module requires six (6) Interconnect Cables (pn# 300815 series cables) and either one (1) HD Wiring Block (pn# 300723) or two (2) Wiring Blocks (pn# 300718). (all sold separately)
150794-200TELSEC® Digital Input Expansion Module (DIEM-200) - A rack mountable expansion module which can be networked via the expansion port on a TELSEC® 2000RM/WM to provide up to an additional two hundred (200) discrete inputs for monitoring of environmental and critical equipment alarms. This module requires eight (8) Interconnect Cables (pn# 300815 series cables) and either one (1) HD Wiring Block (pn# 300723) or two (2) Wiring Blocks (pn# 300718). (all sold separately)
150679TELSEC® 800 - A rack mountable monitoring and control system with 8 universal inputs, 8 digital outputs, and a card access reader port. Includes Temperature Sensor.
150768TELSEC® 2000WM/WME Monitoring and Control Panel - Self contained NEMA rated panel containing the TELSEC® 2000WM, TELSEC® 2000WME, SNMP network module, dial-up modem module, four (4) CIM modules, extension cables, bus expansion cables, and SOLA UPS power supply providing sufficient current for up to four (4) card readers, door controllers, actuators and all other peripheral equipment - including 4-6 hours back-up time.
150771TELSEC® 2000WM Monitoring and Control Panel - Self-contained NEMA rated panel, containing the TELSEC® 2000WM, SNMP network module, dial-up modem module, two (2) CIM modules, extension cables, bus expansion cables, and SOLA UPS power supply providing sufficient current for up to four (4) card readers, door controllers, actuators and all other peripheral equipment - including 4-6 hours back-up time.
150770TELSEC® ESB Panel Controller (24VAC/20-60VDC) - A wall mountable panel with 16 universal inputs, 16 digital outputs, and 2 analog outputs with an integrated 80 character LCD display and 18 button keypad mounted on the front. The system expands to 128 universal inputs, 64 digital outputs, and 10 analog outputs and will support up to 16 RTU controllers. Includes temp/humidity sensor (pn#150749).
150862TELSEC® ESBx Panel Controller (24VAC/20-60VDC) - A wall mountable panel with 16 universal inputs, 16 digital outputs, and 2 analog outputs with an integrated 80 character LCD display and 18 button keypad mounted on the front. The enclosure houses two (2) I/O boards, which can be the Digital Output Boards (pn#130454), Universal Input Boards (pn#130455), and Analog Output Boards (pn#130456). Includes temp/humidity sensor (pn#150749).
130454Digital Output board (DOBv2), (24VAC/20-60VDC) - Eight (8) channel digital output board each consisting of a 10A @ 120VAC Form C relay, on-board on/off/auto bypass, and Isolated M-Bus w/heartbeat. Up to six (6) can be networked to the ESB.
130455Universal Input board (UIBv2), (24VAC/20-60VDC) - Sixteen (16) channel universal input board each capable of measuring 0-6/10VDC or 0/4-20mA, dry contact closures, thermistors, and current output temperature sensors. Built-in transducer support and Isolated M-Bus w/heartbeat. Up to seven (7) can be networked to the ESB.
130456Analog Output board (AOBv2), (24VAC/20-60VDC) - Four (4) channel analog output board each consisting of 0/4-20mA or 0-5/10VDC output, adjustable high/low default setting and Isolated M-Bus w/heartbeat. Up to two (2) can be networked to the ESB.
150775EXP Panel (supports three boards) - The Expansion Board Enclosure houses three (3) I/O boards (panel includes snaptrack). The boards can be the Digital Output Boards (pn#130454), Universal Input Boards (pn#130455), or Analog Output Boards (pn#130456). Requires external power supply.
150860Single Expansion module - The Single Expansion enclosure houses one (1) I/O board. The board can be the Digital Output Board (pn#130454), Universal Input Board (pn#130455), or Analog Output Board (pn#130456).
150663TELSEC® 500 Heat Exchanger Controller - Controls up to 6 fans, up to 4 alarms for intrusion points, fan and fuse failure; includes two temperature sensors (pn#340258) and high temperature alarming.
340258Temperature Sensor - Used with TELSEC® 500 Heat Exchanger Interface Module. Fifteen foot (15') cable length.
150755TELSEC® FCM 2 - The Fan Control Module 2 is a standalone integrated controller for monitoring and controlling the environment inside a Telecommunications cabinet. The TELSEC® FCM 2 controls two (2) fans to maintain the inside temperature of the cabinet.
340287Thermistor Temp Sensor Cable - Used with TELSEC® FCM 2 . Ten foot (10') cable length.
150982RSC 1000™ Site Controller
Intelligent Control and Monitoring System for remote facilities with One or Two Air Conditioning Units. The RSC 1000 has a color touch display for status and programming, 10/100 Mb Ethernet for remote communications, thirteen specific outputs for controlling up to two HVAC systems and eight digital outputs for alarm contacts. The RSC 1000 also has 10 analog and 10 digital inputs for monitoring and management of the remote site and supports Modbus RTU for interfacing with smart equipment such as power meters and generators.
150946Power Supply w/Battery Back-up, 12/24 VDC @ 6 amp - A wall mountable power supply which provides continuous power in the event of a power failure (6-8 Hrs Typical w/1.5 amp load). Input 115 VAC 60Hz @ 2.0A, Output 12 or 24 VDC @ 6 amps distributed via four (4) fused outputs, built-in alarm contacts for ON battery and LOW battery. Includes low battery voltage disconnect module and two (2) 12VDC/10AH batteries.
150985Power Supply w/Battery Back-up, 12/24 VDC @ 10 amp - A wall mountable power supply which provides continuous power in the event of a power failure (6-8 Hrs Typical w/1.5 amp load). Input 115 VAC 60Hz @ 2.0A, Output 24 VDC @ 10 amps distributed via four (4) fused outputs, built-in alarm contacts for ON battery and LOW battery. Includes low battery voltage disconnect module and two (2) 12VDC/12AH batteries.
300847Rack mount UPS (2U), 120 VAC @ 1500VA   - A rack mountable UPS which provides voltage regulation, surge protection, and continuous power in the event of a power failure (4-8 Hrs Typical w/1.5 amp load). Input 115 VAC 60Hz @ 8.5A (max load), Output 120V @ 1500VA/900W distributed via eight (8) 5-15R outlet(s), LCD Display indicates input voltage, battery capacity and a variety of operating conditions. 
300772Wall-Mount Enclosed Power Supply - Input 120 VAC, 50/60 Hz, Input Power Breaker/Switch (10 Amp); Output 24 VDC @ 2.5 Amps.
250090Wall-Mount External Power Supply (wall-plug type) - Input 120 VAC, 60 Hz; Output 24 VDC @ 1 Amps. Powers only one unit.
150987External DC/DC Converter with Enclosure - Input 36-72VDC @ .8A; Output 24VDC @ 1.1A
150763-1Single Phase monitor with enclosure 208/240V - Continuously monitors single phase power lines for abnormal conditions. Adjustable settings for low voltage & high voltage alarm thresholds. Form C alarm relay w/automatic reset. Kit includes (1) UL enclosure, (2) Inline fuses & (2) Power Line Taps (accepts 750 MCM to #3/0 AWG wire).
150947Commercial Power Monitoring Kit - Continuously monitors line voltage for abnormal conditions. 3-Phase monitor detects phase loss, phase reversal, phase unbalance, and low voltage. 1-Phase monitor detects power loss. Form C alarm relay w/automatic reset. Kit includes (1) UL enclosure, (1) 3-Phase Relay (208/480), (1) 240 VAC Relay, (1) 3-pole fuse block & (3) Power Line Taps (accepts 750 MCM to #3/0 AWG wire).
151003Modbus KW Power Meter Bundle 3-Phase
(comes with enclosure, Fuse harness, (3) 18” rope CT’s, (4) B-Taps) - Continuously monitors line voltage for abnormal conditions. Alarm outputs, pulse signals, and Modbus networking utilized. Monitor detects kW, kWh, 3-Phase average current, 3-Phase average voltage, Current by phase, voltage by phase line-line, voltage by line-neutral, 3-phase real power, per phase real power, 3-Phase reactive power, per phase reactive power, 3-Phase apparent power, per phase apparent power, 3-phase average power factor, per phase power factor, frequency, most recent power demand, peak power demand, and demand configuration. Monitor fits on standard DIN rail. Compatible with 90-600 VAC applications.
151004Modbus KW Power Meter Bundle Single Phase
(comes with enclosure, Fuse harness, (2) 18” rope CT’s, (3) B-Taps) - Continuously monitors line voltage for abnormal conditions. Alarm outputs, pulse signals, and Modbus networking utilized. Monitor detects kW, kWh, Single Phase average current, Single Phase average voltage, Current by phase, voltage by phase line-line, voltage by line-neutral, Single phase real power, per phase real power, Single Phase reactive power, per phase reactive power, Single Phase apparent power, per phase apparent power, Single phase average power factor, per phase power factor, frequency, most recent power demand, peak power demand, and demand configuration. Monitor fits on standard DIN rail. Compatible with 90-600 VAC applications.
151016Power & Energy Metering Panel VAC w/Data Logging, I/O, & Network Module - NEMA 4X Rated Polycarbonate panel prewired and configured with Quest's multifunction power and energy meter; Back-lit LCD display; Frequency range 45-65Hz; Works exclusively with Quests Rogowski coil CT’s (5-1200a*); Power supply built in 100-415VAC; RS485 port with Modbus-RTU and DNP3.0 protocol, 8MB onboard memory for data logging, Ethernet module includes HTTP, NTP, SNMP, SMTP, ModbusTCP/IP protocols. I/O module includes 4DI, 2RO, and 2AI’s.
151017Power & Energy Metering Panel VDC w/Data Logging, I/O, & Network Module - NEMA 4X Rated Polycarbonate panel prewired and configured with Quest's multifunction power and energy meter; Back-lit LCD display; Frequency range 45-65Hz; Works exclusively with Quests Rogowski coil CT’s (5-1200a*); Power supply built in 20 -60VDC; RS485 port with Modbus-RTU and DNP3.0 protocol, 8MB onboard memory for data logging, Ethernet module includes HTTP, NTP, SNMP, SMTP, ModbusTCP/IP protocols. I/O module includes 4DI, 2RO, and 2AI’s.
151031Power & Energy Metering Panel VAC (RS-485/ModbusRTU) - NEMA 4X Rated Polycarbonate panel prewired and configured with Quest's multifunction power and energy meter; Back-lit LCD display; Frequency range 45-65Hz; Works exclusively with Quests Rogowski coil CT’s (5-1200a*); Power supply built in 100-415VAC; RS485 port with Modbus-RTU
151032Power & Energy Metering Panel VDC (RS-485/ModbusRTU only)- NEMA 4X Rated Polycarbonate panel prewired and configured with Quest's multifunction power and energy meter; Back-lit LCD display; Frequency range 45-65Hz; Works exclusively with Quests Rogowski coil CT’s (5-1200a*); Power supply built in 20 -60VDC; RS485 port with Modbus-RTU
300798B-Tap Insulation-Piercing Tap Connector - Accepts 750 MCM to #3/0 wire, tap 10/14
150948RTU Bundled package - A wall mountable stand alone and networkable specific purpose controller to monitor and control roof top and remote AC systems. Up to sixteen (16) can be networked to the ESB (only) . Includes supply air temperature (thermistor) sensor with bell box duct mount w/8" probe (pn#300199) and Thermistor 10K bullet probe, 18" (pn#510049).
150858HVAC Monitoring Module - Used to monitor failures on HVAC systems that do not have a built-in alarm contact. Used in conjunction with existing low-voltage thermostat to monitor compressor status and for input power (24 VAC). Includes supply air temperature sensor w/ 8" probe (pn#300199), and enclosure. Optional CT (pn#300781) available for monitoring compressor status on HVAC systems w/built-in controls or proprietary thermostat controls.
150992Battery Discharge Monitor - The Battery Discharge Monitor (BDM) is designed to monitor DC power and provide an alarm indication when the voltage is below a threshold. The unit comes factory calibrated for when the alarm is activated and can be set to the end user's desired level. The BDM has a power LED to indicate proper operation and an alarm LED to notify when an alarm condition is present. The form C relay output is energized under normal operation and closes on a loss of power or when the voltage is below the alarm threshold. This provides a “fail on” alarm condition to ensure proper notification of any power related problem.
150994Wire Harness for Battery Discharge Monitor
No picture140561Mounting Bracket 19" for Battery Discharge Monitor
300850DC Split-Core Bi-Polar Transducer - User adjustable span from ±20A to ±200A, Bi-polar 4-20mA output, 12-24VDC sensor supply voltage
300895DC Shunt Transducer - 3-way isolating amplifier module, with configurable bipolar input/outputs, used for the monitoring of DC shunts. User adjustable input range of ±0-150mV or ±0-3V and output range of 0-20mA or ±0-10V, mounts on DIN Rail (required) (pn#140104), 24 VDC sensor supply voltage (required).
300778Hydrogen Gas Detector (H2, 0-100 %LEL) - Standalone programmable smart gas sensor in NEMA 4X enclosure, 4-line LCD w/backlight screen, integral buzzer, (3) SPDT programmable relays, RS-485 Modbus communication port, (1) 4-20mA analog output, 24/48 VDC or 24 VAC power input (0.3 A). Includes power supply pn#150987.
300779Combustible Gas Detector (CH4, 0-100 %LEL) - Standalone programmable smart gas sensor in NEMA 4X enclosure, 4-line LCD w/backlight screen, integral buzzer, (3) SPDT programmable relays, RS-485 Modbus communication port, (1) 4-20mA analog output, 24 VDC or 24 VAC power input (0.3 A). *If using 48V, must purchase pn#150987.
300151Carbon Monoxide Detector (CO, 0-250PPM) - Standalone programmable smart gas sensor in NEMA 4X enclosure, 4-line LCD w/backlight screen, integral buzzer, (3) SPDT programmable relays, RS-485 Modbus communication port, (1) 4-20mA analog output, 24 VDC or 24 VAC power input (0.3 A).
151022Stand Alone Toxic & Explosive Gas Monitor – Used in conjunction with a TELSEC® system to monitor and alarm if toxic and or combustible gases are present in a facility. This unit derives its power from the TELSEC® system.
151023Toxic and Explosive Gas Monitor – This unit does not require a TELSEC® system. The unit is powered from –48VDC and provides separate contact closures when a toxic or combustible gas is present. Direct replacement for Sierra Monitor 2400 .
150930Infrared Combustible Sensor Module - IT Methane/Propane 0-100% LEL IR with Auxiliary Relay, IT Series
250068External DC/DC Converter w/o Enclosure - Input 36-72VDC @ .8A; Output 24VDC @ 1.1A ( for use with IR Combustible Sensor Module )
300908Enclosed Relay 10Amp DPDT with 24VAC/DC/120VAC Coil
700090Calibration Kit (Type A,) w/o cylinder - Contains a regulator, calibration adapter and carrying case.
700100Gas Cylinder-Methane 50% LEL, (Type A), 105 liters
700110Gas Cylinder Carbon Monoxide, 50ppm (Type A), 103 liters
150671Control Access Module (Multiple Door) - Provides connection to the TELSEC® 1500/2000 RM/WM and TELSEC ® ESB for up to four (4) card readers.
150856Two port card reader module - Provides connection to the TELSEC® 1500/2000 RM/WM and TELSEC® ESB for up to two (2) card readers. Mounted in a standard single gang electrical box.
300117Slim Card reader - A weatherproof card access reader with Wiegand Protocol that is wired to the TELSEC® product and accepts proximity cards. Up to 600 codes can be stored in a single TELSEC® unit. 6.0" x 1.7" x 1.0" (15.2 x 4.3 x 2.54 cm)
300143Keypad/Card reader - The combination keypad/card reader offers Wiegand Protocol interface compatibility with TELSEC® products. To provide an additional level of security, the reader is the first to offer an optional, fully integrated personal identification number keypad, weatherized for outdoor applications. Up to 600 codes can be stored in a single TELSEC® unit. 5.0" x 5.0" x 1.0" (12.7 x 12.7 x 2.54 cm)
300661Mini Card reader - A weatherproof card access reader with Wiegand Protocol that is wired to the TELSEC® product and accepts proximity cards. Up to 600 codes can be stored in a single TELSEC® unit. 3.135" x 1.720" x .660" (7.96 x 4.37 x 1.68cm)
300118Prox card - Used to provide access for keyless entry. Works with Card readers. 3.385" x 2.135" x 0.075" (8.6 x 5.4 x .19cm) Minimum order 50.
150949Door Access Bundle - Includes mag lock (pn#300768), infrared exit switch (pn#300769), power converter (pn#300947), push to exit button (pn#300785), and access control exterior override switch (pn#300839).
300147Electric Door Strike - The electric door strike allows access to the facility when a valid card or code is accepted via the card reader, 12-24VDC/24VAC. *If using 48v, must purchase pn#300947.
300809Industrial Door Intrusion/Contact Sensor - Rugged aluminum housing with armored cable, wide gap (up to 3"), open or closed loop, SPDT.
300842Dual Technology Motion Detector - Power requirement 7.5-16VDC, 25mA
300136Smoke Detector - A low profile, self-diagnostic, four-wire photoelectric smoke detector with a built-in sounder and end of line supervision relay, 12/24VDC. *If using 48v, must purchase pn#300947.
300947DC/DC Converter 24V 20W Din rail mount
150642TELSEC® CIM - The Control Interface Module (CIM) is used when wiring HVAC and other mechanical controls to the TELSEC® product. The CIM connects to the TELSEC® via a 50-pin cable and supports 8 digital outputs and 16 universal inputs. TELSEC® 1500/2000 RM/WM only.
150848Cross Connect Panel bar - Provides screw terminal connection for field wiring termination of monitoring and control points. Cross connect panel supports two (2) 25 pair connectors from the TELSEC® system for a total of 32 inputs and 16 digital outputs. Fits in 19" or 23" rack. TELSEC® 1500/2000 RM/WM only.
300718Wiring Block - The interface block will support four 50-pin connectors to allow for field wiring of environmental and equipment alarms as well as output control points to a TELSEC® system. One block supports 64 universal inputs and 32 digital outputs. Requires mounting bar. TELSEC® 1500/2000 RM/WM only.
300723TELSEC® HD Wiring Block - This interface block will support eight 50-pin connectors to allow for field wiring of environmental and equipment alarms to a TELSEC® Digital Input Expansion Module (only). One block supports 200 digital inputs. Requires mounting bar. TELSEC® 1500/2000 RM/WM only.
30077066 Block - Prewired 50 pair Block with two (2) 25-pair male Amphenol connectors for interface with TELSEC® RM/WM systems. Requires mounting bar. TELSEC® 1500/2000 RM/WM only.
14042819” TELSEC® Mounting Bar for Wiring Block - supports 2 wiring blocks. TELSEC® 1500/2000 RM/WM only.
14042923” TELSEC® Mounting Bar for Wiring Block - supports 2 wiring blocks. TELSEC® 1500/2000 RM/WM only.
150990Mounting bar kit 19" For TELSEC MINI (pn#150963)
150989Mounting bracket kit for TELSEC MINI Pro
300705Interconnect Cable - 5’ (1.5M) Used to connect the TELSEC® RM/WM to either the Control Interface Module (CIM) or Wiring Blocks. One cable supports 8 digital outputs and 16 universal inputs. TELSEC® 1500/2000 RM/WM only.
300705-15Interconnect Cable - 15’ (4.5M) Used to connect the TELSEC® RM/WM to either the Control Interface Module (CIM) or Wiring Blocks. One cable supports 8 digital outputs and 16 universal inputs. TELSEC® 1500/2000 RM/WM only.
300705-25Interconnect Cable - 25’ (7.5M) Used to connect the TELSEC® RM/WM to either the Control Interface Module (CIM) or Wiring Blocks. One cable supports 8 digital outputs and 16 universal inputs. TELSEC® 1500/2000 RM/WM only.
300705-50Interconnect Cable - 50’ (15M) Used to connect the TELSEC® RM/WM to either the Control Interface Module (CIM) or Wiring Blocks. One cable supports 8 digital outputs and 16 universal inputs. TELSEC® 1500/2000 RM/WM only.
300815Interconnect Cable w/Straight Male Connector - 5’ (1.5M) Used to connect the TELSEC® Digital Input Expansion Module (only) to a wiring block. One cable supports 25 digital inputs. TELSEC® DIEM only.
300815-15Interconnect Cable w/Straight Male Connector - 15’ (4.5M) Used to connect the TELSEC® Digital Input Expansion Module (only) to a wiring block. One cable supports 25 digital inputs. TELSEC® DIEM only.
300815-25Interconnect Cable w/Straight Male Connector - 25’ (7.5M) Used to connect the TELSEC® Digital Input Expansion Module (only) to a wiring block. One cable supports 25 digital inputs. TELSEC® DIEM only.
150996Cross-Connect Aggregation Box 128 point- Panel used as a centralized demarcation of facility alarms, supports up to 128 inputs or outputs, includes 128 dual row screw type terminal blocks, NEMA 1 enclosure (20x20x6)
151005Cross-Connect Aggregation Box 200 point - Panel used as a centralized demarcation of facility alarms, supports up to 200 inputs or outputs, includes 200 dual row screw type terminal blocks, NEMA 1 enclosure (24x24x6)
150681Zone temperature (thermistor) sensor - Indoor wall mount enclosure
150745-COutdoor Temperature (thermistor)/Light Level sensor, 4-20mA , 5V output - Sealed weatherproof combination outdoor temp sensor and light level sensor. 24VDC Power required.
150747Outdoor Temperature sensor (thermistor) - Weather resistant
150747-COutdoor Temperature sensor (thermistor) - Weather resistant
150749Zone temperature sensor (thermistor)/Humidity (3%/4-20mA) Wall Mount
300199Supply air temperature (thermistor) sensor, bell box duct mount w/8" probe
300790Strap-on Temperature Sensor (Thermistor), bell box enclosure
300792Outdoor Temperature (Thermistor) /Humidity (5%/4-20mA) Sensor, 24 VDC
510049Thermistor 10K bullet probe, 18" wire lead - Universal sensor used for indoor temp air monitoring applications.
No picture151018Standard Temperature Monitoring Bundle
Includes (2) 8" Duct Mounted Temp Sensors (pn#300199) and (1) Wall Mounted Zone sensor (pn#150681) (For use with RSC1000 only)
No picture151019Extended Temperature Monitoring Bundle
Includes (2) 8" Duct Mounted Temp Sensors (pn#300199), (1) Wall Mounted Humidity/Temp Sensor (pn#150749) and (1) Outdoor Temp Sensor (pn#150747-C). (For use with RSC1000 only)
No picture151020Economizer Monitoring Bundle
Includes (2) 8" Duct Mounted Temp Sensors (pn#300199), (1) Wall Mounted Humidity/Temp Sensor (pn#150749), (1) Outdoor Temp Sensor (pn#150747-C) and (2) Bullet Probe Temp Sensors (pn#510049). (For use with RSC1000 only)
150979Differential Pressure Switch
3007638" Static Pressure Probe, T-6 Aluminum
150822Tower Light Monitor Panel - AC Powered 120VAC. Self-contained NEMA rated panel, consisting of the following items: 1 (2-Lamp Beacon), 2-9 (116W Incandescent), 1 Light Level Sensor. Alarm contacts for Lights Off , B-KON Fail/Steady on, Sidelights/OB Light failure, Beacon Failure and PEC Failure.
150824Tower Light Monitor Panel - AC Powered 240VAC. Self-contained NEMA rated panel, consisting of the following items: 1 (2-Lamp Beacon), 2-9 (116W Incandescent), 1 Light Level Sensor. Alarm contacts for Lights Off , B-KON Fail/Steady on, Sidelights/OB Light failure, Beacon Failure and PEC Failure.
300794Obstruction Lamp Alarm Relay - Used to provide remote monitoring of steady burning incandescent marker and obstruction lighting. Four onboard switches allow operator programming for lighting systems with two through nine lamps on a single AC circuit. Uses a toroidal sensor and electronic circuitry to sense the failure of one or more lamps.
300796Flasher and Beacon Alarm Relay - Used to monitor the operation of one two-lamp incandescent beacon and one beacon flasher. The flasher and lamps are monitored by sensing the flow of current in the circuit. If the lamp(s) or the flasher fail to operate properly, a solid state output and an isolated SPDT relay energize.
151006CT Junction Box
24 VDC Power and Terminations for three Current Transducers (12x12x4)
300781Split Core Current Sensor (on/off) - Solid state switch, SPST, 30VAC/DC, 0.4 Amps max (terminal strip, accepts #14-22 AWG wire), 0.35-150 Amp.
300857Split Core Current Transducer - 30/60/120A, 4-20mA output, I.D. .8". Sensor Power 24VDC.
300851Split Core Current Transducer - 300A, 4-20mA output, I.D. 1.4". Sensor Power 24VDC.
300832Split Core Current Transducer - 800A, 4-20mA output, I.D. 2.5". Sensor Power 24VDC.
300868Split Core Current Transducer - 2400A, 4-20mA output, I.D. 2.5". Sensor Power 24VDC.
300904UPS Card APC9613
300905UPS Card Powerware Xslot (Requires pn#200395)
300906UPS Card Bestdock (Requires pn#200395)
300907UPS Card Liebert (Requires pn#200408)
200395Connector DB15 Female to RJ45
200408Connector DB25 Male to RJ45
200449Connector DB9 Male to RJ45
200387Connector DB9 Female to RJ45
350068UPS Alarm Monitoring Cable - 50' (15M) Includes connectors DB-9F, DB-15F & DB-25F to raw end harness. Refer to application note for compatibility.
150827Alarm Annunciator w/Remote Acknowledge – This alarm unit with red, orange, and green light is utilized in facilities where personnel require a visual and audible indication of critical, major, and minor alarms. Includes remote acknowledge button for silencing horn. 24/48VDC Power Input.
300190Moisture/Spot Leak Detector, 24VAC/DC. 12/24VDC Power required.
300896Enclosed Relay 20Amp, SPDT with 24VAC/DC, 208-277VAC/120VAC Coil
300909Enclosed Relay 10Amp DPDT with 24VAC/DC/208-277VAC Coil
300917LPG Gas Level Sensor
150999Ultrasonic Fuel Level Transmitter 4-20mA output. 24VDC Power Source Required.
130435-1TELSEC ESB PCB
130411TELSEC RM/WM PCB
130440RTU replacement PCB
150780TELSEC ESB replacement keypad/display
15076910Base-T Network Module - Supports SNMP V1 & V2C protocols, Telnet, Email/Paging Alarm Notification, & Web Browser based HTML Configuration. For TELSEC® 1500/2000 RM/WM only.
300179Ethernet Module replacement for TELSEC RM/WM
250080Replacement Battery for UPS Power Supply (Fits power supply pn#150946) - 12V 10aH. Must purchase 2.
250089Replacement Battery for UPS Power Supply (Fits power supply pn#150985) - 12V 12aH. Must purchase 2.
300768Magnetic Door Lock - Magnetic Door Lock operates on 12 -24VDC or DC, Fail Safe, additional door status, 1,500 pounds holding force, can be installed on in and out swinging doors. *If using 48v, must purchase pn#300947.
300769Infrared Exit Switch - Motion detector passive infrared exit switch, used for automatic exit release, 12/24V AC/DC.
300785Push to Exit Button - Works with Magnetic Lock (pn#300768). Illuminated Green.
300839Access Control Exterior Override Switch
150802Indoor Temp/Humidity Sensor (AD592) with Mounting Enclosure (For TELSEC RM/WM only)
300126Temperature Sensor (AD592) - 8” Duct Mount
300127Outside Temperature Sensor (AD592)
300206Indoor Temperature Sensor (AD592) with Wall Mount housing
300131Temperature Sensor (AD592) - Probe with 18” Wire Lead
340267Temp sensor cable (AD592) - 10 ft (3.048m)
300719Battery Temperature Sensor (AD592)
150820Light Level 12/24V IN, 5V OUT
340091In-Line Fuse Assy - Includes 2A 250V 3AG fuse
240046Snap track for mounting I/O Expansion boards - 12" length
140104DIN Rail 35mm x 7.5mm, 3" length
150101Resistor kit for Current Transducers - Contains qty (10) 100 Ohm resistors and qty (10) 249 Ohm resistors