Quest Controls Inc.

QCDOCS

TELSEC® 1500WM
P/N 150617
Brochure
User’s Manual for
WEB ENABLED VERSION
User’s Manual for
TL1 VERSION
Installation Worksheet Startup Checklist    
—————————————————————————————————————————————————————————————————————
TELSEC® 2000WM
P/N 150612
Brochure
User’s Manual for
WEB ENABLED VERSION
User’s Manual for
TL1 VERSION
Installation Worksheet Startup Checklist    
—————————————————————————————————————————————————————————————————————
TELSEC® 1500RM
P/N 150619
Brochure
User’s Manual for
WEB ENABLED VERSION
User’s Manual for
TL1 VERSION
Installation Worksheet Startup Checklist    
—————————————————————————————————————————————————————————————————————
TELSEC® 2000RM
P/N 150618
Brochure
User’s Manual for
WEB ENABLED VERSION
User’s Manual for
TL1 VERSION
Installation Worksheet Startup Checklist    
—————————————————————————————————————————————————————————————————————
TELSEC® 2000WM Panel
P/N 150771
Brochure
User’s Manual Installation Worsheet Startup Checklist  
—————————————————————————————————————————————————————————————————————
TELSEC® 2000WM/WME Panel
P/N 150768
Brochure
User’s Manual      
—————————————————————————————————————————————————————————————————————
TELSEC® ESB
P/N 150770
Brochure
User’s Manual Programmer’s Manual Installation
Manual
   
—————————————————————————————————————————————————————————————————————
TELSEC® 800
P/N 150769
Brochure
User’s Manual for
WEB ENABLED VERSION
User’s Manual for
TL1 VERSION
     
—————————————————————————————————————————————————————————————————————
TELSEC® 500
P/N 150663
Brochure
User’s Manual      
—————————————————————————————————————————————————————————————————————
CGSM
P/N 300150/300152
Brochure
User’s Manual      
 
         
—————————————————————————————————————————————————————————————————————
ADAM™ 720
P/N 150636
Brochure
User’s Manual ADAM™ 720
Peripheral Equipment
   
—————————————————————————————————————————————————————————————————————
         
 
COMMERCIAL PRODUCTS

—————————————————————————————————————————————————————————————————————  
Q3™ Energy Management System
Brochure
User’s Manual
Installation
Instructions
Typical New Store
Construction Drawings
Typical New Store
Construction Drawings
 
—————————————————————————————————————————————————————————————————————  
Q3™ RTU
Brochure
User’s Manual Typical New Store
Construction Drawings
   
       
—————————————————————————————————————————————————————————————————————
BACnet T-Stat
Brochure
User’s Manual    
  —————————————————————————————————————————————————————————————————————

QCDocs Peripherals

Part NumberSpec SheetManualNameDescription
150858Spec SheetHVAC Cooling MonitorUsed to monitor failures on HVAC systems that do not have a built‐in alarm contact . Used in conjunction with existing low‐voltage thermostat to monitor compressor status and for input power (24 VAC). Includes supply air temperature sensor w/ 8" probe (pn#300199), and enclosure. Optional CT (pn#300781) available for monitoring compressor status on HVAC systems w/built‐in controls or proprietary thermostat controls.
130454Spec Sheet ManualDigital Output board (DOBv2)24VAC ‐ Eight (8) channel digital output board each consisting of a 10A @ 120VAC Form C relay, on‐board on/off/auto bypass, and Isolated M‐Bus w/heartbeat. Up to six (6) can be networked to the ESB.
130455Spec SheetManualUniversal Input board (UIBv2)24VAC ‐ Sixteen (16) channel universal input board each capable of measuring 0‐6/10VDC or 0/4‐20mA, dry contact closures, thermistors, and current output temperature sensors. Built‐in transducer support and Isolated M‐Bus w/heartbeat. Up to three (3) can be networked to the ESB.
130456Spec SheetManualAnalog Output board (AOBv2)24VAC ‐ Four (4) channel analog output board each consisting of 0/4‐20mA or 0‐5/10VDC output, adjustable high/low default setting and Isolated M‐Bus w heartbeat. Up to two (2) can be networked to the ESB.
150775Spec SheetEXP Panel (supports three boards)The Expansion Board Enclosure houses three (3) I/O boards. The boards can be the Digital Output Boards v2 (Pn#130454), Universal Input Boards v2 (Pn#130455), or Analog Output Boards v2 (Pn#130456). Requires external power supply.
150860Spec SheetSingle expansion moduleThe Single Expansion enclosure houses one (1) I/O board. The board can be the Digital Output Board v2 (Pn#130454), Universal Input Board v2 (Pn#130455), or Analog Output Board v2 (Pn#130456).
150640TELSEC® RMEA rack mountable expansion module which can be networked via the expansion port on a TELSEC® 1500RM or TELSEC® 2000RM to provide an additional 32 universal inputs and 16 digital outputs.
150724Spec SheetTELSEC® WMEA wall mountable expansion module which can be networked via the expansion port on a TELSEC® 1500WM or TELSEC® 2000WM to provide an additional 32 universal inputs and 16 digital outputs.
150794‐
100/150/200
Spec SheetTELSEC® Digital Input Expansion Module (100/150/200)A rack mountable expansion module which can be networked via the expansion port on a TELSEC® 2000RM/WM to provide an additional one hundred (100) discrete inputs for monitoring of alarms. This module requires four (4) Interconnect Cables (pn# 300815 series cables) and either one (1) HD Wiring Block (pn# 300723) or one (1) Wiring Block (pn# 300718). (all sold separately)
340258Temperature SensorUsed with TELSEC® 500 Heat Exchanger Interface Module. Fifteen foot (15') cable length.
150755Spec SheetTELSEC® FCM2The Fan Control Module 2 is a standalone integrated controller for monitoring and controlling the environment inside a Telecommunications cabinet. The TELSEC® FCM2 controls two (2) fans to maintain the inside temperature of the cabinet.
340287Thermistor Temp Sensor CableUsed with TELSEC® FCM2. Ten foot (10') cable length.
15076910BaseT Network Module (Built‐in)Supports SNMP V1 & V2C protocols, Telnet, Email/Paging Alarm Notification, & Web Browser based HTML Configuration. For TELSEC® 1500/2000 RM/WM only. (Must be Preordered)
300165QSpec SheetEthernet Module (Built‐in)Web Browser enabled Communications Module providing 10 BaseT connectivity to the ESB. For alarm callout and remote programming and interrogation. Supports Email (SMTP) and SNMP v1/v2c communications for interrogation and alarm transportation. For ESB only.
300204Spec SheetDial‐up 56K ModemUsed to connect with a central alarm facility. With a modem, the controller can report alarms, be interrogated and reprogrammed from a secure location. TELSEC® 1500/2000 RM/WM supports up to two (2) modems. TELSEC® ESB supports one (1) modem.
150946Spec SheetPower Supply w/Battery Back‐up, 12/24 VDC @ 6 ampA wall mountable power supply which provides continuous power in the event of a power failure (6‐8 Hrs Typical w/1.5 amp load). Input 115 VAC 60Hz @ 2.0A, Output 12 or 24 VDC @ 6 amps distributed via four (4) fused outputs, built‐in alarm contacts for ON battery and LOW battery. Includes low battery voltage disconnect module and two (2) 12VDC/10AH batteries.
300830Spec SheetDual Feed DC Power Input ModuleDin rail mounted decoupling module. Runs at 10‐60VDC, 0‐10A.
150947Spec SheetCommercial Power Monitoring KitContinuously monitors line voltage for abnormal conditions. 3‐Phase monitor detects phase loss, phase reversal, phase unbalance, and low voltage. 1‐Phase monitor detects power loss. Form C alarm relay w/automatic reset. Kit includes (1) UL enclosure, (1) 3‐Phase Relay (208/480), (1) 240 VAC Relay, (1) 3‐pole fuse block & (3) Power Line Taps (accepts 750 MCM to #2/0 AWG wire).
300148Spec SheetHydrogen Gas DetectorUsed to monitor Hydrogen gas in facilities. The sensor interfaces to a TELSEC® product for power and alarm detection.
150963Spec SheetManualTELSEC MINIQuest TELSEC® MINI is designed to provide advanced monitoring and control for very small remote facilities and cabinets using industry standard communications protocols for alarming such as SNMP traps and Emails over Ethernet. The system has a built in web server for status review and programming and can be polled using SNMP Gets.
150975Spec SheetManualTELSEC MINI PLUSQuest TELSEC MINI PLUS is designed to provide advanced monitoring and alarming for small remote facilities and cabinets using industry standard communications protocols such as SNMP and SMTP (Email) over Ethernet. The system has a built in web server for status review and programming and can be polled using SNMP Gets.
150998-xSpec SheetManualTELSEC MINI PROQuest TELSEC MINI PRO is designed to provide advanced monitoring and alarming for small remote facilities and cabinets using industry standard communications protocols such as SNMP and SMTP (Email) over Ethernet. The system has a built in web server for status review and programming and can be polled using SNMP Gets. The MINI PRO has up to 32 universal inputs for monitoring temperature, humidity, contact closures and any 0-6 VDC or 0-20 mA sensors.
150742 Spec SheetInstallation InstructionsZone Temperature SensorThe Quest wall mount sensor is designed to provide accurate and reliable readings of the zone temperature to provide optimum control of the HVAC equipment. The sensor is housed in a aesthetically pleasing housing that prevents false reading due to drafts and infiltration of
temperature through the wall.
150763-1Spec SheetSingle Phase MonitorContinuously monitors single phase power lines for abnormal conditions. Adjustable settings for low voltage & high voltage alarm thresholds. Form C alarm relay w/automatic reset. Kit includes (1) UL enclosure, (2) Inline fuses & (2) Power Line Taps (excepts 750 MCM to #3/0 AWG wire).
510049Spec SheetBullet ProbeThermistor 10K bullet probe, 18” wire lead ‐ Universal sensor used for indoor temp air monitoring applications.
150992.pdfSpec SheetBattery Discharge MonitorThe Battery Discharge Monitor (BDM) is designed to monitor DC power and provide an alarm indication when the voltage is below a preset threshold.