Quest Controls, Inc electroninc monitoring, control and test solutions for telecom

PERIPHERALS

HOME


Click the links below to download a peripheral specification sheet
[Go to ADAM™ 720 Peripheral Equipment Section]

TELSEC® Video Camera
P/N 300750
The TELSEC® Camera provides access surveillance in your remote site Headend, HUB, or OTN. The camera can be viewed and controlled from the alarm center over Ethernet video stream, SMTP, and FTP.

Fan Control Module (FCM2)
P/N 150755
The Quest TELSEC® Fan Control Module (FCM2) is designed to work as a standalone integrated controller for monitoring and controlling the environment inside a Telecommunications cabinet.

4 Port PPP Serial Bridge with CSU/DSU option
P/N 150697

for TCP/IP connectivity over PPP via a DDS circuit for the TELSEC® 800, 1500RM, and 2000RM

4 Port PPP/Async Serial Bridge
Preordered Option: P/N 150691
Field Upgrade Kit: P/N 150693

Quest Controls’ 4 port PPP/Async serial bridge offers north and southbound communications options for your TELSEC®800, 1500RM and 2000RM.

TELSEC® I/O Expansion Board
P/N 130412
The TELSEC® 1500E is an expansion board designed to plug into the master board of the TELSEC® 1500WM (P/N 150617) and the TELSEC® 1500R (P/N 150619) providing an additional 16 universal inputs and 8 digital control outputs.

TELSEC® RME Shelter Expansion Module
P/N 150640
The rack-mounted expansion module allows the TELSEC® 2000RM (P/N 150618) or TELSEC® 1500WM (P/N 150617) to expand to an additional 32 inputs (analog or digital) and 16 digital outputs.

Digital Output Board
P/N 150574
The Digital Output Board provides eight (8) Form “C” relays rated at 10 amps. The relays are energized and de-energized
in response to commands sent to the DOB from the TELSEC® ESB and Q3™. A bypass LED, status LED, and bypass switch are associated with each relay. The bypass switch allows manual override of controller commands.

Universal Input Board
P/N 150155
The Universal Input Board (UIB) accepts sixteen (16) inputs and converts external sensor outputs to digital values that are transmitted across the communication M-BUS to the TELSEC® ESB and Q3™. The UIB accepts a variety of input sensors including: Temperature, Humidity, Light level, Pressure, and dry contacts.

Analog Output Board
P/N 150156

The Analog Output Board (AOB) provides four (4) separate output channels, with each channel configurable to a current (4 to 20mA) output, or a voltage (0 to 5V/10V) output. Outputs are comunicated via the Communication BUS to the TELSEC® ESB and Q3™. The AOB drives a variety of output devices including: variable speed motors, variable position dampers, or other variably controlled devices.

Expansion Board Enclosure
P/N 150595
The Expansion Board Enclosure houses two (2) I/O boards. The boards can be the Universal Input Board (P/N 150574-01),Digital Output Boards (P/N 150573-01),and Analog Output Boards (P/N 150592-01.)

Expansion Board Enclosure
P/N 150595-48
The Expansion Board Enclosure houses two (2) I/O boards. The boards can be the Universal Input Board (P/N 150574-48), Digital Output Boards (P/N 150573-48), and Analog Output Boards (P/N 150592-48).

Outside Temperature Sensor
P/N 300127
The Outside Temperature Sensor, a current transducing device, measures ambient air temperature. The sensor provides an accurate linear output to the TELSEC® system. The Outside Temperature Sensor is used by the TELSEC® system to monitor the outside air temperature to determine if the vent fan can be used for free cooling or set the HVAC system into economizer mode to reduce electrical consumption.

Battery Temperature Sensor
P/N 300719
The Battery Temperature Sensor is used in conjunction with the TELSEC® System to alert to any anomalous temperature readings. The sensor is attached to the battery post, typically in the middle of the string for an average temperature reading. The temperature sensor used is a current transducer device that provides an accurate linear output to the TELSEC® system.

Keypad/Card Reader
P/N 300143
The combination keypad/card reader offers Wiegand protocol interface compatibility with TELSEC®, 2000RM, 1500WM, and 2000 products. To provide an additional level of security, the reader is the first to offer an optional, fully integrated personal identification number keypad, weatherized for outdoor applications.

Card Reader
P/N 300117
The Proximity Card Reader boasts a new slim design to match any décor. The attractive new design allows the reader to be mounted indoors or out. The new reader accepts 5-16 Volts, so that one model can meet most voltage requirements. The reader is available with a Wiegand interface and connects directly to a TELSEC® system.

Electric Door Strike
P/N 300147
The Electric Door Strike is equipped with a 24 VDC solenoid that provides silent operation. The Electric Door Strike is designed as a fail-secure device. When power is supplied to the strike, the plunger is retracted and the unit is unlocked. If power fails, the strike is locked and the door is secured. The strike is rated for continuous duty, if needed. Each strike has a mount plate provided for easy installation.

Electric Door Strike
P/N 300147-48

This Electric Door Strike's power supply is 48VDC.

Dial-up or Leased Line Wet Modem
P/N 300157

Alarm Annunciator
P/N 150643
This alarm unit with horn and red light, is utilized in cable vaults, cabinets and other potentially hazardous facilities to be occupied by personnel. This unit derives its power and control from the TELSEC® system. When the TELSEC® is in alarm, the alarm annunicator will provide a continuous audible alarm tone and the red light will turn on.

Visual Alarm Indicator
P/N 150644
The Visual Alarm Indicator Unit, with red and green lights, is utilized in facilities where personnel require a visual status prior to entering a potentially hazardous area. This unit derives its power and control from the TELSEC® product and works with the TELSEC® 2000RM, 1500WM, and 2000.

Relay Interface Module
P/N 150589
The relay interface module is used in conjunction with TELSEC® products when retrofitting CEV’s or shelters. This module is exclusively used for the controlling of the facilities HVAC system and the red/green light entry indicators. Using this module eliminates the costly procedure of installing pilot relays and rewiring the existing mechanical panel. The module is prewired for easy installation providing the ability to control the blower, cooling, heating, dehumidifier, red and green light and monitoring of inside lights.

CIM–Control Interface Module
P/N 150642
The CIM module is designed to allow for low voltage termination of environmental control and monitoring devices. The module interfaces with either the TELSEC® 1500WM or 2000RM through the 50 pin amphenal connector. Up to 8 digital outputs and 16 universal inputs can be wired to the CIM. The CIM’s primary function is to provide terminals for shelter manufacturers to terminate the control and monitoring wiring at the factory. The module can be wall mounted or incorporated into a shelter’s control panel.

Connectorized Wiring Block
P/N 300718
The TELSEC I/O cross-connect block is designed in a connectorized version to easily interface with the TELSEC® 2000 and 1500 control and surveillance systems. The wiring block features a compact 4 3/4" deep frame and is provided with single pre-wired pins to a standard female 50-pin connector, light weight, rugged construction and easy circuit identification, all combine for durability, reliability and ease of installation.

Interconnect Cable
P/N 300705
The 25 pair, 24 gauge, Prestolite Cable is used to connect the TELSEC® system to the wiring block on the Control Interface Module (CIM). The cable is designed with two (2) amphenal connectors, one at each end for direct termination to the wiring block and/or the CIM and the TELSEC system.

Alarm Isolation Unit
P/N 130415
The Alarm Isolation Unit (AIU) is designed to isolate alarm voltages from the TELSEC® unit when another monitoring device is sensing the same point.

12 Volt Battery Monitor
P/N 350054
The battery monitor is specifically designed to monitor individual battery voltage in a four (4) battery string configuration. Used with the TELSEC® 1500/2000, the battery monitor will provide accurate readings of the individual batteries in a 4 battery string to the nearest hundredth of a volt. By monitoring the individual batteries, the TELSEC system can log the battery voltage, alarm based upon high or low voltage and if the voltage differential between batteries in the string is greater than a user defined limit.

Battery String Voltage Monitoring Cable
P/N 350053-15 (15 ft.) (4.5M)
P/N 350053-50 (50 ft.) (15M)
This cable is specifically designed to monitor battery string voltage by the TELSEC® system. In order for the TELSEC® system to monitor voltage, a connection must be made to the positive and negative post on the first and last battery of each string, respectively. The method of the connection varies depending on the type of terminals. Quest provides all wires with 3/8" hole ring terminals. For other size terminals, the ring terminal can be upgraded in the field. Cables can be purchased in two different lengths; 15 ft. (for cabinets) and 50 ft. (for CEV’s and Huts), when ordering, specify length.

Humidity/Temperature Sensors
P/N 15090x-xx
The relative humidity and temperature sensors consist of highly reliable loop powered circuitry designed to provide accurate environmental measurements and work with TELSEC® 2000RM, 1500WM, 2000, and 1000. There are three transmitter versions, and each version is available in either room, duct, or outdoor mount packaging. The humidity portion returns 4-20 mA directly proportional to 0- 100% RH.

Light Level Sensors
P/N 150248
P/N 150248-01
The Light Level Sensor (LLS) converts ambient light level into an analog signal read by the Universal Input Board (UIB). The sensor is used to determine brightness in foot candles, for turning ON and OFF multiple loads based on different foot candle set points. The Light Level Sensor works with TELSEC® 2000RM, 1500WM, and 2000.

Refrigeration Pressure Transducers
P/N 510010 (100#) & 510023 (400#)
The Quest pressure sensors are media compatible pressure transducers designed specifically to meet the needs and requirements of the refrigeration and energy management industries.

ADAM™ 720 Peripheral Equipment

REAL-TIME NETWORK SURVEILLANCE
The ADAM 720 is a network surveillance and management system providing real-time surveillance of every alarm type, from sophisticated fiber optic performance monitoring to the simplest discrete alarm. The ADAM 720 can be deployed in traditional telephone company applications, private networks or stand-alone building alarm applications.
telecommunications control and monitoring
telecommunications control and monitoring


Send mail to info@questcontrols.com with questions or comments about this web site.
Copyright©1999-2008 Quest Controls, Inc. Updated:
03.10.08